Subnet Hyperparameters
This document presents the description of subnet hyperparameters. You can see the subnet hyperparameters by running this below command and selecting the netuid
(i.e., selecting the subnet):
btcli subnet hyperparameters
Setting the hyperparameters
Use the below command to set these hyperparameters:
btcli sudo set
rho, kappa
Description : These two parameters determine how the Yuma Consensus behaves. Generally speaking, they determine how the Yuma Consensus normalizes divergent weights.
Value
: - rho (): Set to 10
.
- kappa (): Set to
32767
.
Setting : Must not be changed.
immunity_period
Description : The immunity period is expressed in number of blocks. The immunity period is the number of blocks given to a subnet miner or a subnet validator at a UID before they are considered available for deregistration.
Value
: Set to 7200
blocks for Subnet-1. The immunity_period
at a UID starts when a subnet validator or a subnet miner is registered into the subnet.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
A subnet miner or a subnet validator at a UID can perform poorly during the immunity_period
without risking deregistration. If the UID still does not perform well even after the expiry of the immunity_period
, then the subnet miner or subnet validator at that UID can be removed from the subnet. They will be removed when a new entity, i.e., a subnet miner or a subnet validator, requests to join the subnet.
When a subnet miner or a subnet validator is deregistered, they are required to register again to be considered for the subnet.
Example
Consider Subnet-1, that has its immunity_period
set to 7200 blocks. The duration of a block is 12 seconds. Hence a subnet validator or a subnet miner at any UID in Subnet-1 has 24 hours (=7200 blocks) from the moment they have registred, before they will be considered for deregistration.
The subnet owner should modify the adjustment_interval
, target_regs_per_interval
and max_regs_per_block
parameters to control the number of UIDs that are within the immunity_period
at any given time.
min_allowed_weights
Description : The minimum number of UIDs a subnet validator must set weights on, before the subnet validator is allowed to set weights on the blockhain.
Value
: Set to 8
for Subnet-1.
: This means that any subnet validator who is trying to set weights on the blockchain must set weights on a minimum of 8 subnet miners before this subnet validator is able to successfully set its weights on the blockchain.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
The value of min_allowed_weights
sets a lower bound for the consensus. A higher value of min_allowed_weights
means that the subnet validators are forced to set weights for more subnet miners. This parameter is mainly for security reasons, to eliminate unreasonably low consensus amongst the subnet validators in the subnet.
Example
A subnet validator can be considered as poorly performing if they set weights on only five subnet miners, when the min_allowed_weights
is set to 8. This might occur due to a variety of reasons, for example: Maybe the subnet validator does not have enough stake to query the subnet miners, or maybe the subnet validator is part of a cabal engaged in cheating the system.
In this case, none of the actual weight-setting extrinsics that the subnet validator sends to the chain will be accepted. Hence on the chain it will look like this subnet validator has not set any weights at all. The Yuma Consensus may conclude that this subnet validator is performing poorly and after the immunity_period
expires, this subnet validator could be deregistered to make room for others waiting to be miners or validators.
max_weight_limit
This is the maximum weight that can be set by a subnet validator for a subnet miner, expressed as a value between 0
and 65535
. This is a u16 (unsigned integer) type.
Value
: Set to 455
for Subnet-1.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
Example
Consider Subnet-1 where max_weight_limit
is set to 455 and min_allowed_weights
is set to 8. This means that each subnet validator must set weights for at least 8 subnet miners, and each such weight must not exceed 455
.
tempo
Description : A duration of a number of blocks. Several subnet events occur at the end of every tempo period. For example, Yuma Consensus runs for the subnet and emissions are transferred to the hotkeys (delegated or staked).
See also Anatomy of Incentive Mechanism.
Value
: Set to 99
blocks for Subnet-1. All user-created subnets are set to 360
blocks.
Setting : Must not be changed.
min_difficulty, max_difficulty
Description : Obsolete. We no longer support PoW (proof-of-work) registration, hence these parameters are no longer used.
weights_version
Description : Indicates the required minimum version of the subnet validator code.
Value
: Set to 2013
for Subnet-1.
: This means that every subnet validator in Subnet-1 must have at least version 2013
of the subnet validaor code.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet. Setting this parameter to a version ensures that all the subnet validators use the same version of the code.
weights_rate_limit
Description : How often a subnet validator can set weights on the blockchain, expressed in number of blocks.
Value
: Set to 100
for Subnet-1.
: This means that after a subnet validator in Subnet-1 sends the weights to the blockchain, this subnet validator must wait for at least 100 blocks before sending the weights again to the blockchain.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
adjustment_interval
Description
: Expressed in number of blocks. This is the number of blocks after which the recycle register cost and the pow_register
difficulty are recalculated.
If the number of actual registrations that occurred in the last adjustment_interval
is higher than the target_regs_per_interval
, then the blockchain will raise the recycle register cost, by increasing the min_burn
value by a certain amount, in order to slow down the actual registrations and bring them back to target_regs_per_interval
value.
Value
: Set to 112
for Subnet-1.
: The blockchain uses this parameter together with the target_regs_per_interval
and the min_burn
and max_burn
parameters.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
Example
The Subnet-1 has its target_regs_per_interval
set to 2. Consider a scenario where, in a 112-block interval (adjustment_interval
) this subnet had 6 registrations. This is higher than target_regs_per_interval
. The blockchain will now raise the minimum cost to recycle register, by increasing the min_burn
value by a certain amount, in order to slow down the actual registrations.
The subnet owner should modify the adjustment_interval
, target_regs_per_interval
and max_regs_per_block
parameters to control the number of UIDs that are within the immunity_period
at any given time.
activity_cutoff
Description
: Expressed in number of blocks. If a subnet validator has not set weights on the blockchain for activity_cutoff
duration, then the Yuma Consensus will consider this subnet validator as offline, i.e., turned off. The weights of this subnet validator are considered too old to be useful. The weights of this subnet validator slowly lose their impact over time and eventually will no longer be considered for consensus calcuation.
Value
: Set to 5000
(blocks) for Subnet-1.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
registration_allowed
Description
: True
or False
. Indicates whether this subnet allows registrations.
Value
: Set to True
for Subnet-1.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
target_regs_per_interval
Description
: The target number of registrations desired in a adjustment_interval
period. Expressed as an integer number.
The maximum number of registrations that can occur in an adjustment_interval
is (3 * target_regs_per_interval
).
Value
: Set to 1
for Subnet-1.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
The subnet owner should modify the adjustment_interval
, target_regs_per_interval
and max_regs_per_block
parameters to control the number of UIDs that are within the immunity_period
at any given time.
min_burn, max_burn
Description : Minimum and maximum cost to register on this subnet. Expressed in Rao (10-9 TAO).
Setting : This parameter is automatically updated by the blockchain.
bonds_moving_avg
Description
: This parameter controls how fast bonds will decay in the entire subnet. This is a unit-less number. This number has a direct impact on subnet validator. The faster the bonds decay the quicker a subnet validator will lose its dividends after the subnet validator is out of the activity_cutoff
.
If this bonds_moving_avg
value is low, then the moving average of the bonds will decay slowly. This will allow the subnet validator to become active again, start setting new weights and start earning new bonds.
If this bonds_moving_avg
value is high, then bonds in the subnet decay quickly. As a result, a subnet validator who has fallen out of the activity_cutoff
and hence is running the risk of being viewed as "turned off", may not be able to become active again.
Value
: Set to 900000
for Subnet-1.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
max_regs_per_block
Description : Maximum allowed registrations in this subnet per block.
Value
: Set to 1
for Subnet-1.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
The subnet owner should modify the adjustment_interval
, target_regs_per_interval
and max_regs_per_block
parameters to control the number of UIDs that are within the immunity_period
at any given time.
serving_rate_limit
Description : Determines how often you can change your node's IP address on the blockchain. Expressed in number of blocks. Applies to both subnet validator and subnet miner nodes. Used when you move your node to a new machine.
Value
: Usually this is set to 100
blocks.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.
max_validators
Description : Determines the maximum number of subnet validators you can have in the subnet.
Value
: Default value is 64
.
Setting : This parameter can be changed by the subnet owner. The value of this parameter varies from subnet to subnet.